0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
THN 30-2411WI

THN 30-2411WI

  • 厂商:

    TRACOPOWER

  • 封装:

    -

  • 描述:

    THN 30-2411WI

  • 数据手册
  • 价格&库存
THN 30-2411WI 数据手册
DC/DC Converter THN 30WI Series, 30 Watt • Highest power density 30 W Converter! Ultra compact size: 1.0" x 1.0" x 0.4" • Shielded metal case with isolated baseplate • • Ultrawide 4:1 input voltage range • • • • • • Very high efficiency across full load range up to 92% UL 62368-1 IEC 62368-1 Over temperature protection The THN 30WI series is the latest generation of high performance DC/DC converter modules with highest power density. The product achieves 30 W output Operating temp. range: –40°C to +80°C power while it comes in a metal case with dimensions of only 1.0" x 1.0" x and up to 85°C with heat sink 0.4". All models have an ultra wide 4:1 input voltage range and precisely regulated output voltages, even under no load conditions. Highest efficiency across Ultra low no load input current full load range makes this product very reliable and applicable in temperature Remote On/Off control and output ranges of up to 85°C. With a low input current at minimal load and remote On/voltage adjustable Off control these converters are the ideal solution for battery-operated systems. Typical applications are in mobile equipments, instrumentation, distributed I/O isolation voltage 1600 VDC power architectures in communication and industrial electronics and every3-year product warrenty where where space on the PCB is critical. Models Order Code Input Voltage Range THN 30-2410WI THN 30-2411WI THN 30-2411WI-A1 THN 30-2412WI THN 30-2413WI THN 30-2415WI THN 30-2422WI THN 30-2423WI THN 30-2425WI THN 30-4810WI THN 30-4811WI THN 30-4811WI-A1 THN 30-4812WI THN 30-4813WI THN 30-4815WI THN 30-4822WI THN 30-4823WI THN 30-4825WI 9 - 36 VDC (24 VDC nom.) 18 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 5 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC +24 VDC 3.3 VDC 5 VDC 5 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC +24 VDC 7'000 mA 6'000 mA 6'000 mA 2'500 mA 2'000 mA 1'250 mA 1'250 mA 1'000 mA 625 mA 7'000 mA 6'000 mA 6'000 mA 2'500 mA 2'000 mA 1'250 mA 1'250 mA 1'000 mA 625 mA Vnom Efficiency Imax –12 VDC –15 VDC –24 VDC 1'250 mA 1'000 mA 625 mA –12 VDC –15 VDC –24 VDC 1'250 mA 1'000 mA 625 mA typ. 88 % 89 % 88 % 89 % 89 % 90 % 89 % 91 % 91 % 88 % 90 % 89 % 90 % 91 % 92 % 91 % 92 % 92 % Options THN-HS1 Note - Optional Heat Sink: www.tracopower.com/products/thn-hs1.pdf - Suffix -A1: Adjustable output up to 6 VDC, suitable for low ripple & noise applications in conjunction with an LDO regulator. - ±24 Vout models: The output can also be used in serial circuit for single 48 VDC operation. www.tracopower.com November 30, 2022 Page 1 / 4 THN 30WI Series, 30 Watt Input Specifications Input Current - At no load 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: 24 Vin models: 48 Vin models: Surge Voltage Under Voltage Lockout Reflected Ripple Current Recommended Input Fuse 10 mA typ. 8 mA typ. 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 7.5 VDC min. / 8 VDC typ. / 8.8 VDC max. 15.5 VDC min. / 16 VDC typ. / 17.5 VDC max. 30 mAp-p typ. 24 Vin models: 6'000 mA (slow blow) 48 Vin models: 3'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Input Filter Output Specifications Output Voltage Adjustment See application note: Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) - Cross Regulation (25% / 100% asym. load) - single output - dual output Capacitive Load - single output - dual output single output models: dual output models: single output models: dual output models: dual output models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 24 / -24 Vout models: 3.3 Vout models: 5 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 24 / -24 Vout models: Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response - Response Time –10% to +20% (A1, 15 & 24 Vout models) ±10% (other models) (By external trim resistor) www.tracopower.com/overview/thn30wi Output power must not exceed rated power! ±1% max. 0.2% max. 0.5% max. 0.2% max. 1% max. (Output 1) 1% max. (Output 2) 5% max. 75 mVp-p typ. (w/ 22 µF, 25 V X7R) 75 mVp-p typ. (w/ 22 µF, 25 V X7R) 75 mVp-p typ. (w/ 2x 22 µF, 25 V X7R) 75 mVp-p typ. (w/ 2x 22 µF, 25 V X7R) 75 mVp-p typ. (w/ 2x 6.8 µF, 50 V X7R) 60 / 60 mVp-p typ. (w/ 10 µF, 25 V X7R) 60 / 60 mVp-p typ. (w/ 10 µF, 25 V X7R) 75 / 75 mVp-p typ. (w/ 4.7 µF, 50 V X7R) 10'000 µF max. 7'200 µF max. 1'200 µF max. 1'000 µF max. 375 µF max. 750 / 750 µF max. 500 / 500 µF max. 180 / 180 µF max. Not required ±0.02 %/K max. 30 ms max. Continuous, Automatic recovery 150 - 205% of Iout max. 170% typ. of Iout max. 112 - 164% of Vout nom. 250 µs typ. (25% Load Step) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4 THN 30WI Series, 30 Watt Safety Specifications Safety Standards EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/thn30wi PD 2 OVC I - IT / Multimedia Equipment - Certification Documents Pollution Degree Over Voltage Category EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions EMS Immunity External filter proposal: Air: Contact: - Electrostatic Discharge - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 55032 class A (with external filter) EN 55032 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/thn30wi EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A 24 Vin models: 220 µF, 100 V // TVS SMDJ58A 48 Vin models: 220 µF, 100 V EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Protection Mode - Measurement Point Cooling System Remote Control - Voltage Controlled Remote - Off Idle Input Current - Remote Pin Input Current Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability - Input to Output, 60 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF 95% max. (non condensing) –40°C to +80°C +105°C max. –55°C to +125°C Depending on model Depending on model (with Heat Sink) See application note: www.tracopower.com/overview/thn30wi 105°C min. / 130°C typ. / 115°C max. (Automatic recovery at 100°C typ.) Case Natural convection (20 LFM) On: 3.0 to 15 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin 2 mA max. -0.5 to 1.0 mA 5'000 m max. 275 kHz typ. (PWM) (±10%, 3.3 & 5 Vout model) 330 kHz typ. (PWM) (±10%, other models) Functional Insulation 1'600 VDC 1'000 VDC 1'000 VDC 1'000 MΩ min. 1'500 pF max. 1'200'000 h (MIL-HDBK-217F, ground benign) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4 THN 30WI Series, 30 Watt Washing Process See Cleaning Guideline: Environment - Vibration - Thermal Shock Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Thermal Impedance Allowed (hermetical product) www.tracopower.com/info/cleaning.pdf MIL-STD-810F MIL-STD-810F Copper Non-conductive FR4 (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Nickel (2 - 3 µm) Tin (3 - 5 µm), matte Metal Case PCB Mount THD (Through-Hole Device) 1" x 1" 265°C / 10 s max. 16.5 g 15 K/W typ. 13.8 K/W typ. (with Heat Sink) www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Case to Ambient Environmental Compliance - REACH Declaration - RoHS Declaration Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/thn30wi Outline Dimensions 7.62 5.08 (0.3) (0.2) 1 5.6 9.9 2.5 10.16 (0.22) (0.39) (0.1) (0.4) 3 2.5 4 5 (0.1) Bottom view (1.0) 2 25.4 (0.8) 20.32 6 Pinout Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 3 +Vout +Vout 4 Trim Common 5 –Vout –Vout 6 Remote On/Off Remote On/Off 10.16 (0.4) 25.4 (1.0) Dimensions in mm (inch) Tolerances: ±0.5 (±0.02) Pin pitch tolerances ±0.25 (±0.01) Pin diameter Ø 1.0 (0.04) © Copyright 2022 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4
THN 30-2411WI 价格&库存

很抱歉,暂时无法提供与“THN 30-2411WI”相匹配的价格&库存,您可以联系我们找货

免费人工找货
THN 30-2411WI
    •  国内价格
    • 1+874.85401
    • 5+789.99317
    • 10+768.99667

    库存:0